Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.

B Ghai, A Sharma, S Akhtar 
 Department of Anaesthesia, Maulana Azad Medical College and associated Lok Nayak Hospital, New Delhi, India. , India

Correspondence Address:
B Ghai
Department of Anaesthesia, Maulana Azad Medical College and associated Lok Nayak Hospital, New Delhi, India.
India

AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.


How to cite this article:
Ghai B, Sharma A, Akhtar S. Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube. J Postgrad Med 2001;47:181-4


How to cite this URL:
Ghai B, Sharma A, Akhtar S. Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube. J Postgrad Med [serial online] 2001 [cited 2023 Oct 3 ];47:181-4
Available from: https://www.jpgmonline.com/article.asp?issn=0022-3859;year=2001;volume=47;issue=3;spage=181;epage=4;aulast=Ghai;type=0


 
Tuesday, October 3, 2023
 Site Map | Home | Contact Us | Feedback | Copyright  and disclaimer