Journal of Postgraduate Medicine
 Open access journal indexed with Index Medicus & ISI's SCI  
Users online: 4164  
Home | Subscribe | Feedback | Login 
About Latest Articles Back-Issues Articlesmenu-bullet Search Instructions Online Submission Subscribe Etcetera Contact
 
  NAVIGATE Here 
 ::   Next article
 ::   Previous article
 ::   Table of Contents

 RESOURCE Links
 ::   Similar in PUBMED
 ::  Search Pubmed for
 ::  Search in Google Scholar for
 ::Related articles
 ::   Citation Manager
 ::   Access Statistics
 ::   Reader Comments
 ::   Email Alert *
 ::   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed9642    
    Printed396    
    Emailed9    
    PDF Downloaded176    
    Comments [Add]    
    Cited by others 5    

Recommend this journal


 

 BRIEF REPORT
Year : 2001  |  Volume : 47  |  Issue : 3  |  Page : 181-4

Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.


Department of Anaesthesia, Maulana Azad Medical College and associated Lok Nayak Hospital, New Delhi, India. , India

Correspondence Address:
B Ghai
Department of Anaesthesia, Maulana Azad Medical College and associated Lok Nayak Hospital, New Delhi, India.
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 11832619

Rights and PermissionsRights and Permissions

AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation. RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation. CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.






[FULL TEXT] [PDF]*


        
Print this article     Email this article

Online since 12th February '04
© 2004 - Journal of Postgraduate Medicine
Official Publication of the Staff Society of the Seth GS Medical College and KEM Hospital, Mumbai, India
Published by Wolters Kluwer - Medknow