Journal of Postgraduate Medicine
 Open access journal indexed with Index Medicus & ISI's SCI  
Users online: 2523  
Home | Subscribe | Feedback | Login 
About Latest Articles Back-Issues Articlesmenu-bullet Search Instructions Online Submission Subscribe Etcetera Contact
 
  NAVIGATE Here 
  Search
 
 :: Next article
 :: Previous article 
 :: Table of Contents
  
 RESOURCE Links
 ::  Similar in PUBMED
 ::  Search Pubmed for
 ::  Search in Google Scholar for
 ::Related articles
 ::  [PDF Not available] *
 ::  Citation Manager
 ::  Access Statistics
 ::  Reader Comments
 ::  Email Alert *
 ::  Add to My List *
* Registration required (free) 


  IN THIS Article
 ::  Introduction
 ::  Case report
 ::  Discussion
 ::  References

 Article Access Statistics
    Viewed9602    
    Printed173    
    Emailed3    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal


   
Year : 1986  |  Volume : 32  |  Issue : 1  |  Page : 42-4

Full thickness replacement of the abdominal wall with synthetic mesh (a report of 2 cases).







How to cite this article:
Shah R S, Parulkar B G, Samsi A B, Mathur S K. Full thickness replacement of the abdominal wall with synthetic mesh (a report of 2 cases). J Postgrad Med 1986;32:42


How to cite this URL:
Shah R S, Parulkar B G, Samsi A B, Mathur S K. Full thickness replacement of the abdominal wall with synthetic mesh (a report of 2 cases). J Postgrad Med [serial online] 1986 [cited 2023 Jun 2];32:42. Available from: https://www.jpgmonline.com/text.asp?1986/32/1/42/5375




  ::   Introduction Top

Synthetic meshes have been used to reinforce abdominal wall repairs since many years.[11],[13] The peritoneum, and, when possible, the fascia are repaired on either side of the mesh.[10]
Recent experimental and clinical work challenge many of the dogmas about abdominal wall closure; it has been shown that a synthetic mesh alone can provide adequate replacement for the full-thickness of the abdominal wall, substituting adequately for all layers including peritoneum, muscle, fascia and skin, in an emergency situation.[1],[3],[6],[7],[14]
We present our experience and observations in two cases where a synthetic mesh was used to replace the full-thickness of abdominal wall and emphasize the fallacy of several conventional beliefs.

  ::   Case report Top

Case 1
A 35 year old female patient presented with a desmoid tumour of the lower anterior abdominal wall. At surgery the tumour was found to be involving the rectus sheath, muscle, peritoneum, omentum, a loop of the ileum and the fundus of the urinary bladder. The skin was free. Wide excision of the tumour produced a defect of 14 cm x 5 cm involving the full-thickness of the abdominal wall except skin. As it was not possible to close the peritoneum or the musculo-aponeurotic defect (without excesssive tension) the defect was bridged by a single layer of polypropylene mesh placed directly between intestines and skin [Fig. 1] and overlapping the wound margins by 1.5 cm. A Redivac suction tubing was positioned between the mesh and the skin. Drainage was profuse for the first 48 hours, but gradually became negligible by the sixth day. The wound healed without complications. At three months follow up, the repair was firm and strong with no obstructive symptoms or incisional hernia.
Case 2
A 50 year old male presented with a midline supraumbilical, 10cm x 4cm incisional hernia, following previous surgery for a duodenal ulcer. He also had a gastric ulcer, visualised on endoscopy, which had net responded to conservative treatment. Haematological investigations were within normal limits.
The patient was explored through a midline, supraumbilical incision (excising the previous scar) with a view to perform definitive surgery for the gastric ulcer and to repair the hernia. The patient was found to have miliary tuberculosis (confirmed on biopsy) involving the entire peritoneal cavity including stomach and duodenum. There was minimal ascites. It was decided to close the abdomen, performing only a speedy, simple repair of the hernia.
A tense anatomical closure was considered ill-advised. Hence the defect was bridged with a single layer of prolene mesh. Since the peritoneum was very flimsy, omentum alone was partially interposed between the mesh and the intestines. Skin was closed over a drainage tube. The post-operative period was stormy. The patient required cardiorespiratory support for persistent hypotension and chest infection. The skin stitches had to be removed because of wound infection, leaving the mesh and underlying intestines exposed to the exterior. The mesh was kept covered with moist antiseptic gauze dressings. Ascitic fluid leaked for 8-10 days.
The patient ultimately recovered from the acute crisis. It was possible to observe the behaviour of the exposed mesh. Initially a bed of granulation tissue formed on the under surface. Slowly this penetrated the interstices of the mesh, progressively incorporating it. The wound became narrower as a result of wound contraction and epithelial growth from the margins.
At this juncture, crimping of the mesh was observed, with small areas of the mesh forming ridges that rose above the general surface. These parts of the mesh remained free of granulation tissue. Hence we never obtained a uniformly granulating surface that would accept a skin graft. At three months the mesh was completely covered with epithelium. The mesh was incorporated into a fibrous sheet which was firm and strong with no tendency towards herniation.

  ::   Discussion Top

Large defects of the abdominal wall may be encountered during the repair of giant incisional hernia[12] or following acute losses as a result of trauma,[8] surgical excision for tumours[9] (Case 1), infection,[3] gas gangrene[7] or electric burns.[1]
Conventional methods of closure of such large defects are tedious and unsuitable in acute conditions-especially in the presence of infection, respiratory complications or multisystem failure. A polypropylene mesh provides an easy, safe, and quick way of repairing abdominal wall defects by substituting for the full-thickness of the abdominal wall. This is useful in emergency as well as planned surgery and is of special value in the presence of infection and multisystem failure[14] as observed in our second case.
Some points need to be emphasized. Peritoneal closure is not essential in abdominal wall closure, with or without a mesh. Experimental and clinical work reveal:
1) that the peritoneum regenerates de novo and not from the cut edges of a defect,[4],[5]
2) absence of peritoneum does not make the wound weak,[2]
3) a mesh left in direct contact with the bowels is rapidly lined by peritoneum with minimal adhesions[6] and does not carry an increased risk of adhesive obstruction.[1],[14]
These observations are found to be valid in both of our cases, none of whom developed adhesive intestinal obstruction in a follow up of 1 year.
Infection is not a contraindication to the use of a mesh as seen in our second case; in fact transmesh drainage may be of special therapeutic value in cases with peritonitis.[14] At the end of complete healing the block of fibrous tissue incorporating the mesh, has enough strength to prevent development of any incisional hernia.[6] This is quite evident from our present cases, neither of whom developed an incisional hernia subsequently.
A primary skin cover over the mesh is not essential. Subsequent cover may be achieved by permitting spontaneous epithelialisation and wound contraction (Case 2), by split thickness skin grafting or by mobilisation of skin flaps.
Crimping of the mesh (Case 2) can be avoided by taking stitches perpendicular to the edge of the mesh, avoiding gathering' and by suturing the mesh flat with no bulging.[6]
It is important to ensure that wound margins are viable and that non-absorbable synthetic stitches are used.[14]

  ::   References Top

1.Boyd, W. C.: Use of Marlex mesh in acute loss of the abdominal wall due to infection. Surg. Gynaecol. and Obstet., 144: 251-252, 1977.  Back to cited text no. 1    
2.Ellis, H. and Heddle, R.: Does the peritoneum need to be closed at laparotomy. Brit. J. Surg., 64: 733-736, 1977.  Back to cited text no. 2    
3.Gilsdorf, R. B. and Shea, M. M.: Repair of massive septic abdominal wall defeats with Marlex mesh. Amer. J. Surg., 130: 634-638,1975.  Back to cited text no. 3    
4.Hubbard, T. B. Jr., Khan, M. Z., Carag, V. R., Albites, V. E., Hricko, G. M.: The pathology of peritoneal repair. Its relations to the formation of adhesions. Ann. Surg., 165: 908-916, 1967.  Back to cited text no. 4    
5.Karipineni, R. C., Wilk, P. J. and Danese, C. A.: The role of the peritoneum in the healing of abdominal incisions. Surg. Gynaecol. and Obstet., 142: 729-730, 1976.  Back to cited text no. 5    
6.Lamb, J. P., Vitale, T. and Kaminski. D. L.: Comparative evaluation of synthetic meshes used for abdominal wall replacement. Surgery, 93: 643-648, 1983.   Back to cited text no. 6    
7.Long, W. B., Howatson, A. and Gill, W.: Marlex mesh in gas gangrene. J. Trauma, 16: 948-953, 1976.  Back to cited text no. 7    
8.Mathes, S. J. and Stane, H. H.: Acute traumatic losses of abdominal wall substance. J. Trauma, 15: 386-391, 1975.  Back to cited text no. 8    
9.Mays, E. T., Weakley, S.: Alloplasty of the abdominal wall after extensive cancer surgery. Amer. J. Surg., 122: 781-784, 1971.  Back to cited text no. 9    
10.Notoras, M. J.: Mesh prosthesis in the repair of large incisional hernias. In: "Abdominal operations." 7th edition, Editor: Rodney Maingot, Appleton Century Crofts, New York, 1980, pp. 1637-1643.   Back to cited text no. 10    
11.Ogilvie, W. H.: The late complications of abdominal war wounds. Lancet, 2: 253-256, 1940.  Back to cited text no. 11    
12.Smith, R. S.: The use of prosthetic materials in the repair of hernias. Surg. Clin. North Amer., 51: 1387-1389, 1971.   Back to cited text no. 12    
13.Usher, F. C., Fries, J. G., Ochsner, J. L. and Tuttle, L. L. D.: Marlex mesh -a new plastic mesh for replacing tissue defects. Arch. Surg., 78: 138-145, 1959.   Back to cited text no. 13    
14.Wouters, D. G., Krom, R. A. F., Sloof, M. J. H., Kootstra, G. and Kuijjer, P. J.: The use of Marlex mesh is patients with generalised peritonitis and multiple organ system failure. Surg. Gynaecol. and Obstet. 156: 609-614, 1983.  Back to cited text no. 14    

Top
Print this article  Email this article
Previous article Next article
Online since 12th February '04
© 2004 - Journal of Postgraduate Medicine
Official Publication of the Staff Society of the Seth GS Medical College and KEM Hospital, Mumbai, India
Published by Wolters Kluwer - Medknow